X-Ray Fluorescens spectrometer
Quality and Technical CURATIO Bureau (Environmental Directive)
RoHS/Rohs (China)/ELF/EN71
Toy
Charta, Ceramici, Pingere, Metallum, &c.
Electrica et electronic materias
Semiconductores, materiae magneticae, solidae, partes electronicae, etc.
Ferro, metallis non ferreis
Admixtis metallis, scoria, chalcitide, etc.
chemica industria
Productorum mineralium, fibrarum chemicarum, catalystae, coatingae, fuci, fuci, etc.
environment
Solum, cibus, vastitas industriae, pulvis carbonarius
Oleum
Oleum, oleum lubricatum, oleum grave, polymerum, etc.
alius
Crassitudo efficiens mensurae, carbones, archaeologiae, inquisitiones materiales et forenses, elc.
● Tria genera radiorum X radiorum salutis systemata, interlocks programmatibus, interlocks odiosis, et interlocks mechanica, lacus radiophoniciorum sub quavis conditione operante penitus eliminabunt.
● Lineamenta XD-8010 singulariter designata via optica, quae minimizat distantias inter fontem X-radii, exempli, et detectoris, servato flexibilitate mutandi inter varios filorum et collimatores.Hoc signanter ampliat sensum, et modum deprehendendi demittit.
● Magnum volumen specimen cubiculi sinit magna exemplaria directe enucleari sine necessitate damni vel praetractationis.
● Simplex, una-analysis bullarum utens programmate convenienti et intuitivo interface.Disciplina professionalis ad principalem instrumenti operationem non requiritur.
● XD-8010 celeri analysi elementorum elementorum ab S ad U praebet, temporibus analysi congruis.
● Usque ad 15 coniunctiones eliquarum et collimatorum.Filtra variarum crassitudinum ac materiarum in promptu sunt, necnon collimatores vndique a Φ1 mm usque ad Φ7 mm.
● Renuntiatio potentissima pluma formatting permittit ad flexibilem customizationem analyseos automatice generatae.Renuntiationes generatae in PDF et in Excel formats salvari possunt.Data analysi statim post singulas analysin reposita est.Historical notitia et statistica quolibet tempore accedere possunt ex interrogatione simplici interfaciei.
● Usura instrumenti specimen camerae, locum specimen observare potes ad umbilicum fontis X-radii.Picturae specimen sumuntur cum analysis incipit ac exponi possunt in fama analysi.
● Spectra comparationis instrumentum utile est ad analysin qualitativam ac materialem identitatem ac comparationem.
Utendo methodis probatis et efficacibus analysi qualitivae et quantitatis, subtilitas eventuum certificari potest.
● Curva calibratio aperta et flexibilis, apta lineamentis variis applicationibus utilis est, sicut detectio substantiarum noxiarum.
Noxia methodo elementum analysis
Ancipitia substantiae | Exemplum | |
Contegendo Analysis | Detailed analysis | |
Hg | X-ray spectroscopia | ASS |
Pb | ||
Cd | ||
Cr6 + | X spectroscopia (Analysis totalis Cr) | Ion fina |
PBBs / PBDEs | X spectroscopio-radius (Analysis totalis Br) | GC-MS |
Qualitas Processus Management
Mensurae noxiae vestigium elementi in speciminibus polyethylenis, ut Cr, Br, Cd, Hg et Pb.
• Valorum dati differentia ac valores ipsas Cr, Br, Cd, Hg et Pb.
Differentia valorum dati et valorum ipsius Cr, (Unit: ppm)
Sample | Datum Precium | Valor actualis (XD-8010) |
Blank | 0 | 0 |
Sample 1 | 97.3 | 97.4 |
Sample 2 | 288 | 309.8 |
Sample 3 | 1122 | 1107.6 |
Differentia valorum datorum et valorum ipsorum Br, (Unit: ppm).
Sample | Datum Precium | Valor actualis (XD-8010) |
Blank | 0 | 0 |
Sample 1 | 90 | 89.7 |
Sample 2 | 280 | 281.3 |
Sample 3 | 1116 | 1114.1 |
Differentia valorum datorum et valorum ipsorum Cd (Unit: ppm)
Sample | Datum Precium | Valor actualis (XD-8010) |
Blank | 0 | 0 |
Sample 1 | 8.7 | 9.8 |
Sample 2 | 26.7 | 23.8 |
Sample 3 | 107 | 107.5 |
Differentia valorum dati et valorum actualium og Hg, (Unit: ppm)
Sample | Datum Precium | Valor actualis (XD-8010) |
Blank | 0 | 0 |
Sample 1 | 91.5 | 87.5 |
Sample 2 | 271 | 283.5 |
Sample 3 | 1096 | 1089.5 |
Differentia valorum datorum et valorum ipsorum Pb, (Unit: ppm).
Sample | Datum Precium | Valor actualis (XD-8010) |
Blank | 0 | 0 |
Sample 1 | 93.1 | 91.4 |
Sample 2 | 276 | 283.9 |
Sample 3 | 1122 | 1120.3 |
Repetita mensurae specimen specimen 3 Cr1122ppm, Br116ppm, Cd10ppm, Hg1096ppm, Pb1122ppm (Unit: ppm)
Cr | Br | Cd | Hg | Pb | |
1 | 1128.7 | 1118.9 | 110.4 | 1079.5 | 1109.4 |
2 | 1126.2 | 1119.5 | 110.8 | 1072.4 | 1131,8 |
3 | 1111.5 | 1115.5 | 115.8 | 1068.9 | 1099.5 |
4 | 1122.1 | 1119.9 | 110.3 | 1086.0 | 1103.0 |
5 | 1115.6 | 1123.6 | 103.9 | 1080.7 | 1114.8 |
6 | 1136.6 | 1113.2 | 101.2 | 1068.8 | 1103.6 |
7 | 1129.5 | 1112.4 | 105.3 | 1079.0 | 1108.0 |
Mediocris | 1124.3 | 1117.6 | 108.2 | 1076.5 | 1110.0 |
Vexillum digredior | 8.61 | 4.03 | 4.99 | 6.54 | 10.82 |
RSD | 0.77% | 0.36% | 4.62% | 0.61% | 0.98% |
Secundarium colum pro Pb elemento (Speel substratum exempla), Sample: Ferro (Pb 113ppm)
1.X radiatio radiophonica e tubo primario X-ray, per collimatorem ad sample irradiatum.
2. Primary X radius excitatio notarum elementorum in sample X-radiorum contentarum per collimatorem secundarium in detectorem
3.Processed per detector formans fluorescens spectroscopium data
4.Computer spectroscopia notata analysi, qualitativa et quantitativa analysi completur
Model | NB-8010 | |
Analysis principium | Energy digerat X-ray fluorescens analysis | |
Elementa Range | S (16)U (92) aliquod elementum | |
Sample | Plastic / metal / pellicula / solid / liquida, pulveris, etc., quantitatis et figurae irregularis | |
X - ray tube | Target | Mo |
Tubus voltage | (5-50) kV | |
Tubus current | (10-1000) et alii | |
Sample irradiatio diametri | F1mm-F7mm | |
Saccare | XV mutatoriae compositae filter automatice delectus et conversio latae | |
Detector | Importat ex Civitatibus Foederatis Americae Si-ACUS detector | |
MGE circuitu tabula | Importat a eros, in usum Si-ACUS detector occidere | |
Sample observationis | Cum 300,000-pixel CCD camera | |
Sample cubiculum magnitudine | 490 (L).´430 (W).´150 (H). | |
Analysis methodo | Lineae lineares, codicis quadratici lineae; vi et concentration calibratiis disciplinam | |
Sistema operatum software | Windows XP, Windows7 | |
Data procuratio | Praecedo notitia procurationis, relationes probatae; PDF / Excel forma servata | |
Operatio environment | Temperature: £30°C. Umor £ LXX% | |
Pondus | 55kg | |
Dimensiones | 550´450´395 | |
Virtus copia | AC220V±10%, 50/60Hz | |
Determinatio conditionibus | Atmosphaerica environment |